Transducer Box

Data Logging Unit (Pressure, Temperature, Analog, and Digital Sensors)

Data Logging Unit (Pressure, Temperature, Analog, and Digital Sensors)

This unit is available in two types: 

Siemens Transducer Box 

Delta Transducer Box 

Siemens Transducer Box:

This unit is designed and manufactured for transmitting data to the test room software. It includes a specialized box for installing temperature and pressure sensors along with the relevant connectors. In this unit, modular data acquisition cards are installed, and data is transmitted using the PROFINET (Industrial Ethernet) protocol. It is capable of sending data over long distances (up to 100 meters). The data logging unit and acquisition system are produced by Siemens, and the number of channels is configured based on the required sensors.

Technical Specifications:

Analog Output Module SM332: 8 AO

Digital Input/Output Module SM323: 8DI/8DO

Analog Input Module SM331: 8 AI

Temperature Sensor Input Module (Thermocouple) SM331: 8 TC

Communication Protocol: PROFINET

Delta Transducer Box:

This unit is designed and manufactured for transmitting data to the test room software. It includes a specialized box for installing temperature and pressure sensors, along with the necessary connectors. In this unit, modular data logging cards are installed, and data is transmitted using the ETHERNET protocol. It supports data transmission over long distances (up to 100 meters). The data logging unit and cards are produced by the Taiwanese company Delta Electronics, and the number of channels is configured based on the required sensors.

Technical Specifications:

Data Logger Device by Delta

Digital Input/Output Module: DVP16SP11R/T

Analog Input Module: DVP04AD-S

Temperature Sensor Input Module (Thermocouple) DVP04TC-S