Transducer Box
Data Logging Unit (Pressure, Temperature, Analog, and Digital Sensors)
Data Logging Unit (Pressure, Temperature, Analog, and Digital Sensors)
This unit is available in two types:
Siemens Transducer Box
Delta Transducer Box
Siemens Transducer Box:
This unit is designed and manufactured for transmitting data to the test room software. It includes a specialized box for installing temperature and pressure sensors along with the relevant connectors. In this unit, modular data acquisition cards are installed, and data is transmitted using the PROFINET (Industrial Ethernet) protocol. It is capable of sending data over long distances (up to 100 meters). The data logging unit and acquisition system are produced by Siemens, and the number of channels is configured based on the required sensors.
Technical Specifications:
Analog Output Module SM332: 8 AO
- Adjustable voltage or current output
- Voltage output ranges: 0-10V, -10 to 10V, -5 to 5V
- Current output ranges: 4-20mA, 0-20mA, -20 to 20mA
- Output settling time: 2 milliseconds for resistive load
- 12-bit input resolution
Digital Input/Output Module SM323: 8DI/8DO
- 16 channels (8 input channels / 8 output channels)
- Switching frequency of outputs: 100 Hz for resistive load
Analog Input Module SM331: 8 AI
- Adjustable voltage or current input
- Voltage input ranges: 0-10V, -10 to 10V, -5 to 5V
- Current input ranges: 4-20mA, 0-20mA, -20 to 20mA
- 13-bit input resolution
- Data preparation time (INTEGRATION TIME): 50 milliseconds
Temperature Sensor Input Module (Thermocouple) SM331: 8 TC
- 16-bit input resolution
- Data preparation time (INTEGRATION TIME): 10 milliseconds
- Capable of reading thermocouples of types B, E, J, K, L, N, R, S, T, U
Communication Protocol: PROFINET
Network type: An advanced, scalable communication system based on Ethernet
Technology: Highly flexible with line, bus, star, or tree topology depending on the connected equipment.
Installation: Switched Ethernet transmission with shielded cables and RJ45 or M12 connectors, or fiber-optic media.
Data rate: 100 Mbps
Maximum stations: Nearly unlimited
Data: Each node: maximum 1500 bytes per telegram frame, total: almost unlimited
Network Features: A scalable communication system based on switched Ethernet technology with real-time performance, advanced configuration, diagnostics, and alarm management systems.
Delta Transducer Box:
This unit is designed and manufactured for transmitting data to the test room software. It includes a specialized box for installing temperature and pressure sensors, along with the necessary connectors. In this unit, modular data logging cards are installed, and data is transmitted using the ETHERNET protocol. It supports data transmission over long distances (up to 100 meters). The data logging unit and cards are produced by the Taiwanese company Delta Electronics, and the number of channels is configured based on the required sensors.
Technical Specifications:
Data Logger Device by Delta
- Maximum data transfer speed: 12 Mbit/s
- Sampling rate: 1ms
- Voltage protection level: 500 VDC
- Operating temperature range: 0-60°C
- Protection level: IP20
Digital Input/Output Module: DVP16SP11R/T
- 16 channels (8 input channels / 8 output channels)
- Switching frequency of outputs: 100 Hz for resistive load
Analog Input Module: DVP04AD-S
- Adjustable voltage or current input
- Voltage input ranges: 0-10V, -10 to +10V
- Current input ranges: 4-20mA, 0-20mA
- 13-bit input resolution
- Data preparation time (INTEGRATION TIME): 80 ms
Temperature Sensor Input Module (Thermocouple) DVP04TC-S
- 12-bit input resolution
- Data preparation time (INTEGRATION TIME): 40 ms
- Capable of reading thermocouples of types J, K, R, S, T